MULTI-STAGE /                                solids handling
    multi-outlet

     CF                                          SHM                                         SHL

     Industry                                    Water  Industry                             Water  Industry

    cONFIGURAtION                                cONFIGURAtION                               cONFIGURAtION
    Multi-stage pump with modular                Horizontal non-clog pumps having single     Horizontal and vertical single stage solids
    construction                                 stage, single suction with back pull out    handling pump
                                                 type design

    DISchARGE & PERFORmANcE                     DISchARGE & PERFORmANcE                   DISchARGE & PERFORmANcE
    • Delivery size up to 50 mm                 • Delivery up to 200 mm                     • Delivery up to 900 mm
    • Outputs up to 20 m3/h                      • Outputs up to 800 m3/h                    • Outputs 13,000 m3/h
    • Head up to 315 m                           • Head up to 90 m                           • Heads up to 82 m
    • Temp up to 120 °C
                                                                                            FEAtURES
                                                                                             • Solids handling up to 300 mm
    FEAtURES                                     FEAtURES                                    • Mechanical seal or gland packed
    • Channel multi-stage, Modular Construction  • Back pull-out design                      • Impeller enclosed or semi open type
    • Gland Packed / Mechanical Seal             • Solids handling up to 105 mm              • Grease or oil lubrication
    • Electrical Drive / Engine Drive            • Impeller type non clog                    • Available in various materials
    • Self priming                               • Oil or grease lubricated bearing housing
    • Conforming to DIN 24254                    • Mechanical seal or gland packed
                                                 • Temp up to 140 °C